Do you have any data available about misalignment tolerances for the 15F series?

How big can the misalignment tolerance be between the center of the stud and the center of the receptacle?   Unfortunately we have no data available about the requested tolerances for a misalignment.   The outer diameter of the spring cup is 7,9 mm. The recommended panel preparation is 8,2 +/- 0,1 mm. Only the difference between both could be explained as a possibility for a small misalignment.   If this is not sufficient an extended hole in the panel could be an improvement. The recommendation from our engineering is a maximum of 8,5 mm. This should still be validated by the customer (by testing) to see if the function of the system is still assured.     This question applies to the following parts:
  • camloc 15F series stud: 15S1-*-1AD
  • camloc 15F series stud: 15S1-*-1AJ
  • camloc 15F series receptacle: V15R13-1-1AB
The 15F series studs require the retaining washer 15S11-1CJ . The 15F series receptacle is mostly installed using the nut V15R14-1-1AB .